DLT VS80 Tape Drive Installation and Operations Guide
001596-01 Rev A07 May 2004 3-11
3.3.2 Configuring Your Internal Tape Drive
The following sections explain how to configure your internal tape drive.
Setting the SCSI ID
All SCSI devices that are attached to the server or workstation must have a unique SCSI ID. Check the
SCSI IDs on all other devices on the selected server or workstation, including the SCSI host bus
adapter, and select an unused SCSI ID for your tape drive. The factory default SCSI ID is 5drive’s
factory default SCSI ID is not being used, you do not need to change the SCSI ID.
NOTE: If the tape drive is attached to a narrow SCSI bus, you can only use IDs 0
through 7. If it is a wide SCSI bus, then you can use IDs 0 through 15.
1. Locate the SCSI ID jumpers on the rear panel of the tape drive as shown in Figure 3-6.
2. Use the supplied jumpers to set the desired SCSI ID, as shown in the following table:
Figure 3-6. Back Panel Connections, Internal Tape Drive
Table 3-1. Selecting the SCSI ID
SCSI ID
01234
5
a
a. Factory default SCSI ID
67
Jumper
Block
SCSI ID 8 9 10 11 12 13 14 15
Jumper
Block
68-pin SCSI connector
Power connector
SCSI ID jumpers