![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/8f/08f3eb34-10cb-4058-9c0c-27ba8dab4b5d/08f3eb34-10cb-4058-9c0c-27ba8dab4b5d-bga.png)
Page 10 of 12 2475SDB - Rev: 1/21/2014 7:58 AM
Voltage
120VAC +/- 10%, Split, Single Phase
240VAC +/- 10%, Single Phase
277VAC +/- 10% Three Phase
20 Amps;1800 Watts (for incandescent loads)
Wired-in incandescent lighting and inductive loads
Retains all settings without power
Yes, all saved in Non-volatile EEPROM
Standby power consumption
ETL (Intertek Testing Services)
X10 Features (applies to power line only)
Troubleshooting
The Status LED on In-
LineLinc is not turning
on and won’t control
the load.
In-LineLinc may not be
getting power.
Make sure the circuit breaker is turned on.
Check the junction box wires to ensure all
connections are tight and no bare wires are
In-LineLinc won’t link
or work with a
controller.
The controller might have
been reset without
Unlinking In-LineLinc from
Re-Link In-LineLinc to the controller.
The INSTEON signal may
be too weak.
Add additional INSTEON devices or move around
existing INSTEON devices. All INSTEON devices
act as INSTEON network repeaters.
Large appliances, such as
refrigerators or air
conditioners, may be
producing electrical noise
Install a power line noise filter (#1626-10) to filter
electrical noise and minimize signal attenuation.