18 Sun Blade X6440 Server Module Product Notes November 2009
Hard disk error message in the SP event log
The following error message might appear in the SP event log when no hard disk is
installed.
System Firmware Error | Unrecoverable hard-disk controller
failure | Asserted
Workaround:
It is safe to ignore this error message.
DIMM SPD data are reported incorrectly in the
FRU data
Certain DDRII DIMMs are displayed incorrectly in the SP FRU data. For example,
DDRII 800 MHz DIMMs are listed only as 444 MHz DIMMs in the FRU data. This is
a FRU data discrepancy and it does not impact memory and system performance.
Workaround:
This issue is scheduled to be fixed in a future ILOM firmware release.
Diagnostics Issues
This section contains the following:
“Pc-Check Diagnostics Software Issues” on page 18
“Hard disk information is unknown” on page 19
“Serial port test fails” on page 19
“SunVTS Diagnostics Software Issues” on page 19
“SunVTS I/O port test fails” on page 19
Pc-Check Diagnostics Software Issues
The following issues apply to the Pc-Check diagnostics software.