A SERVICE OF

logo

Chapter 34 Access Control
MGS-3712/MGS-3712F User’s Guide
308
34.3.3 SNMP Traps
The Switch sends traps to an SNMP manager when an event occurs. The following
tables outline the SNMP traps by category.
An OID (Object ID) that begins with “1.3.6.1.4.1.890.1.5.8” is defined in private
MIBs. Otherwise, it is a standard MIB OID.
Table 103 SNMP System Traps
OPTION OBJECT LABEL OBJECT ID DESCRIPTION
coldstart coldStart 1.3.6.1.6.3.1.1.5.1 This trap is sent when the
Switch is turned on.
warmstart warmStart 1.3.6.1.6.3.1.1.5.2 This trap is sent when the
Switch restarts.
fanspeed FanSpeedEventOn MGS-3712F:
1.3.6.1.4.1.890.1.5.8.48.2
5.2.1
MGS-3712:
1.3.6.1.4.1.890.1.5.8.47.2
5.2.1
This trap is sent when the fan
speed goes above or below the
normal operating range.
FanSpeedEventClear MGS-3712F:
1.3.6.1.4.1.890.1.5.8.48.2
5.2.2
MGS-3712:
1.3.6.1.4.1.890.1.5.8.47.2
5.2.2
This trap is sent when the fan
speed returns to the normal
operating range.
temperature TemperatureEventOn MGS-3712F:
1.3.6.1.4.1.890.1.5.8.48.2
5.2.1
MGS-3712:
1.3.6.1.4.1.890.1.5.8.47.2
5.2.1
This trap is sent when the
temperature goes above or
below the normal operating
range.
TemperatureEventClear MGS-3712F:
1.3.6.1.4.1.890.1.5.8.48.2
5.2.2
MGS-3712:
1.3.6.1.4.1.890.1.5.8.47.2
5.2.2
This trap is sent when the
temperature returns to the
normal operating range.