A SERVICE OF

logo

15
NOTE: The configurations for Valve3 and Valve4 are identical. However, if Heater2 was enabled, then the Valve4
configuration will not appear (a single relay is used to implement either the Heater2 function or the Valve4 function-
-it can not do both).
This menu will appear only if Valve3 is configured for timeclock. The valve will rotate on and
off at the designated times.
This menu will appear only if the valve3 is configured for countdown timer. This setting is
the time after you manually turn on the valve3 relay until the Aqua Logic automatically turns
off the relay. You can also manually turn off the valve at an earlier time by pressing the
VALVE3 button.
Super Chlorinate
24 hours
A
djust Superchlorination period (1 - 96 hours)
Move to previous/next menu item
+
>
>
Larger pools or when you have an unusually high bather load, a large amount of rain, a
cloudy water condition, or any other condition that requires a large amount of chlorine to be
introduced to the pool, may require more hours of Superchlorination. Smaller pools require
less hours of Superchlorination.
Group Function
The latest version of the Aqua Logic offers the ability to assign a Group function to a particular button.
Instead of a button controlling one particular function, the button can be programmed to initiate a sequence
of commands that are programmed in the Configuration Menu. For example, instead of the Lights button
turning on and off the pool light only, the button can be programmed to turn on the pool light, turn on the
bug light, turn off the pool cleaner, turn on and dim the patio lights, turn on the music, etc. all at the same
time. This convenient feature is offered on all Aux buttons, both Valve buttons and the Lights button. Refer
to this section when programming Group commands.
Before assigning and configuring all the desired functions and their control parameters, the group itself must
be configured. The options for controlling groups are Manual On/Off, Countdown Timer, and Timeclock.
The group will turn on and off based on this selection.
When setting up a Group function in the Configuration Menu, the first menu allows you to select the control
parameter (how the group is activated and de-activated) and the second menu allows you to select which
Aqua Logic functions are to be controlled in the group.
Set Day and Time
Wednesday 10:37P
Set Day and Time
Wednesday 10:37P
Adjust time setting
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15...)
Move between start and stop times & to previous/next menu item
Move to previous/next menu item
Valve3-all
8:30A to 4:00P
Valve3-CountDn
0:20
Adjust time s
Adjust time s
Valve3-wkend
8:30A to 4:00P
Valve3-wkday
8:30A to 4:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
+
+
>
>
>
>
+
+
>
>
>
>
or
28
6B Spa Config.
+ to view/change
6B A, Button 1
Pool/Spa
Select 6B Spa
A
Push to access the 6 Button Spa Side Remote options
Rotates between System Off, Pool/Spa, Filter, Lights, Heater1, Valve3,
Valve4, and all available Aux outputs
Rotates between all available remotes
Move to previous/next configuration menu
Move to previous/next menu item or next configuration menu
Move to next menu item
+
+
+
>
>
>
>
>
>
if AQL-SS-6B is connected
Select 6B Spa
This menu only appears if more than one AQL-SS-6B is detected at power up. Select which
of the available remote controls (A, B or C) is to be configured.
6B A, Button 1
This menu allows the user to map each button of the AQL-SS-6B to one of the standard Aqua
Logic functions. The default selections are: Button 1 - Pool/Spa, Button 2 - Filter, Button 3
- Lights, Button 4 - Heater1, Button 5 - Aux1 and Button 6 - Aux2.
Digital Spa Config.
+ to view/change
Digital A, Button 1
Pool/Spa
Digital A, Setpoint
Heater1
Select Digital Spa
A
Push to access the Digital Spa Side Remote options
Rotates between System Off, Pool/Spa, Filter, Lights, Heater1, Valve3,
Valve4, and all available Aux outputs
Rotates between heaters that are enabled
Rotates between all available remotes
Move to previous/next configuration menu
Move to previous/next menu item
Move to previous menu item or next configuration menu
Move to next menu item
+
+
+
+
>
>
>
>
>
>
>
>
if AQL-SS-D is connected
Select Digital Spa
This menu only appears if more than one AQL-SS-D is detected at power up. Select which of
the available remote controls (A, B or C) is to be configured.
Digital A, Button 1
This menu allows the user to map each button of the AQL-SS-D to one of the standard Aqua
Logic functions. The default selections are: Button 1 - Pool/Spa, Button 2 - Filter, Button 3
- Lights, Button 4 - Heater1, Button 5 - Valve3, Button 6 - Valve4, Button 7 - Aux1 and Button
8 - Aux2.
Digital A, Setpoint
If more than one heater is installed, select the spa heater you wish to control. If no heaters
are installed, “Heaters Disabled” will be displayed.
Remote Menus
Enabled
Toggle between Enabled (default) and Disabled Remote Menus
Move to previous/next configuration menu
+
>
>
This feature will prevent unauthorized access to the Settings, Timers, and Configuration
menus from any of the Aqua Logic’s remote display/keypads. When disabled, the remote
display/keypads will only show the default menu and allow on/off control via the pushbuttons.
Note that the function of the Aqua Logic’s built-in display/keypad is unchanged by this
selection. Once disabled, the only way to enable “Remote Menus” is to use the local
display/keypad.