MSR120 Programmer’s Manual UDN PM010, Rev. 1.1
Section 5 – Configuration Commands 2003/1/21
Section 5 CONFIGURATION COMMANDS
This section describes the internal configuration commands available for the MSR120. Each item provides the ASCII,
hexadecimal code and an explanation of the command. The letter “x” indicates a variable and the letter “h” is an
abbreviation of “hexadecimal”. The hardware related configuration commands need to do warm reset before becoming
effective.
Command Form
<09Hex><ADDRESS><command counter Hex><COMMAND><BCC>
Note: Command Length is in hex value.
ESx (45h 53h x) - ES & SS Send Enable/Disable
x = E (45h enable) or D (44h disable)
Table 5-1. ES & SS Send Enable/Disable
Command Form (Hex)
ES&SS Sending
09h 00h 03h 45h 53h 44h 58h Disable
09h 00h 03h 45h 53h 45h 59h Enable (default)
LCx (4Ch 43h x) - LRC Send Enable/Disable
x = E(45h enable) or D(44h disable)
Table 5-2. LRC Send Enable/Disable
Command Form (Hex)
LRC Sending
09h 00h 03h 4Ch 43h 44h 41h Disable (default)
09h 00h 03h 4Ch 43h 45h 40h Enable
PCx (50h 43h x) - Set Protocol of Power On Report
x is an ASCII number (1-3)
Table 5-3. Protocol Setting
ASCII
Command Form (Hex)
Protocol
1 09h 00h 03h 50h 43h 31h 28h Protocol 0 (default)
2 09h 00h 03h 50h 43h 32h 2Bh Protocol 1
3 09h 00h 03h 50h 43h 33h 2Ah Protocol 2
BZx (42h 5Ah x) - Buzzer Enable/Disable
x = E(45h enable) or D(44h disable)
Note: No matter buzzer is enable or not, the reader still can accept Z or z commands to let it beep.
Table 5-4. Buzzer Setting
Command Form (Hex)
Buzzer