8
Pelican Water Systems
877-842-1635, www.pelicanwater.com
This system has been designed for installa on by a licensed professional such as a contractor or plumber. Proper comple on of this installa-
on will require basic familiarity with standard sink plumbing and proper use of common hand and power tools. Improperly installed systems
could result in water damage due to leaks or fl ooding.
System
9.72” W x 13.75” D x 15.38” H
( 24.7 x 34.9 x 39.1 cm), 11 lbs. (5 kg.)
Shipping Box
14.5"L x 11.25"W x 20"H
(36.8 x 28.6 x 50.8 cm), 13.7 lbs. (6.2 kg.)
Dimensions and Weight
A. Product water storage tank
B. Tank valve
C. Tank tubing (3/8” white)
D. Air-gap faucet
E. Drain connec on assembly
F. Drain tubing (3/8” white)
G. Quick connect fi ng
H. Drain tubing (1/4” black)
I. Faucet tubing (3/8” blue)
J. Four-stage desalinator
K. Feed water tubing (1/4” green)
L. Inlet fi ng with shut-off
M. Two-stage remineralizing post-fi lter
A
B
J )
E
F
G
D
K
L
M
I
H
C (not shown)
(behind cover)
Pressure 40-80 psi (275 kPa - 552 kPa)
Temp 40°F - 100°F (4°C - 38°C)
TDS <2000 mg/L
Chlorine <1.0 mg/L
Turbidity <1 NTU
SDI <5
pH 4-8
Performance Specifi ca ons
Feed water must be potable, municipal water. Must
be free of poten al membrane foulants such as Iron,
Hydrogen Sulfi de and Manganese.
Membrane Produc on 50 GPD
System
Produc on 14.61GPD
TDS Rejec on 96.5%
Recovery
1
26.76%
System tested at 50 psig, 750ppm TDS at 77°F.
1
The percentage of the feed water available
as reverse osmosis treated water under
normal opera ng condi ons.
Feed Water Requirements
System Specifi ca ons
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfec on before or a er the system.