Page 10 | DEFENDER™ Vogelzang International Corp. TR001B | 20110118.4
CHIMNEY CONNECTIONS
Fig. 11 - Chimney Construction Through Roof
Chimney Minimum Height Requirements:
(1) Overall Height – 15 ft. min.
(2) Height above roof – 3 ft. min.
(3) Height above slope – 2 ft. min. within 10 ft.
(4) Minimum rise before horiz. section – 24 in.
MANUFACTURED CHIMNEY
REFER TO CHIMNEY AND CHIMNEY CONNEC-
TOR MAKER’S INSTRUCTIONS FOR INSTALLATION
AND USE.
Use only 6” diameter listed chimney UL 103 HT
(U.S.). Chimney made to this listing is High Temperature
rated to 2100 degrees Fahrenheit. Use chimney from
only one manufacturer. Never mix brands. Carefully
follow the chimney manufacturer’s stated requirements
and clearances. Use the chimney manufacturer’s attic
guards, roof supports, flashing and fire stops when
passing through a ceiling. Use a listed thimble when
passing through a combustible wall. Do not use make-
shift compromises during installation. CAUTION: Never
use a single-wall connection pipe as a chimney. A
house fire could result!
When using a pre-existing chimney, have it’s condi-
tion and installation inspected before using. Make sure
that the chimney meets all of the UL rating requirements
listed above. Be aware that not all manufactured chim-
ney is of the UL 103 HT (US).
NOTE: It is recommended that you contact a li-
censed heating and cooling contractor (consult your
local yellow pages) for chimney installation.
Manufactured chimney with the proper required UL
listing is available from most home centers, hardware
stores, and HVAC supply stores.
If you have access to the internet, you may wish
to view chimney manufacturers’ information on-line.
See, www.duravent.com, www.selkirkinc.com, or www.
mtlfab.com.
VENTING TO EXISTING FIREPLACE
In some instances, people desire to convert an ex-
isting fireplace for stove use. Usually, safe connection to
an existing masonry chimney requires more work than
using a prefabricated chimney. The existing fireplace
Fig. 10 - Chimney Construction Through Attic Space
NOTICE: IF MINIMUM CHIMNEY REQUIRE-
MENTS ARE NOT MET, YOUR STOVE WILL NOT
OPERATE PROPERLY.
continued on next page
If the connector stove pipe must go through a
combustible wall before entering the masonry chimney,
consult a qualified mason or chimney dealer. The instal-
lation must conform to local building and fire codes and
latest edition of NFPA 211.
If there is a cleanout opening in the base of the
chimney, close it tightly.