Chapter 4 Maintenance and Troubleshooting 51
4 Replace any fuses that are burnt out (see Section 2.3 on page 26 for fuse information). If
the fuses are not the problem, replace the power module with a new one from the
manufacturer.
5 Slide the power module back into the power module slot.
6 Tighten the thumbscrews.
Figure 29 IES-5000 Power Module
4.2.3 Procedure to Reconnect the Power
1 Reconnect the power wires to the IES-5000’s power module terminals.
2 Reconnect the power wires to the power supply’s power terminals.
3 Turn the power supply back on.
4 Turn the IES-5000 power module switch back to the ON position.
4.3 Hardware Troubleshooting
This section explains how to troubleshoot the system hardware.