A complete list of S-Registers
A-5
A complete list of
S-Registers
.
Register Default Function
S0 0 Sets the number of rings on which to answer in Auto
Answer mode. S0=0 disables Auto Answer. S0=1 enables
Auto Answer and the Business Modem answers on the first
ring.
S1 0 Counts and stores the number of rings from an incoming
call.
S2 43 Stores the ASCII decimal code for the escape code
character. Default character is “+”. A value of 128-255
disables the escape code.
S3 13 Stores the ASCII decimal code for the Carriage Return
character. Valid range is 0-127.
S4 10 Stores the ASCII decimal code for the Line Feed character.
Valid range is 0-127.
S5 8 Stores the ASCII decimal code for the Backspace character.
A value of 128-255 disables the Backspace key's delete
function.
S6 0 Set the number of seconds the Business Modem waits for a
dial tone.
S7 60 Sets the number of seconds the Business Modem waits for
a carrier. May be set for much longer duration if, for
example, the Business Modem is originating an
international connection.
S8 2 Sets the duration, in seconds, for the pause (,) option in the
Dial command and the pause between command
reexecutions (> and A> commands).
S9 6 Sets the required duration, in tenths of a second, of the
remote device's carrier signal before recognition by the
Business Modem.
S10 14 Sets the duration, in tenths of a second, that the Business
Modem waits after loss of carrier before hanging up. This
guard time allows the Business Modem to distinguish
between a line hit, or other disturbance that momentarily
breaks the connection, from a true disconnect (hanging up)
by the remote device
S11 70 Sets the duration and spacing, in milliseconds, of dialed
tones.
S12 50 Sets the duration, in fiftieths of a second, of the guard time
for the escape code (+++) sequence.