440 Application Enhancement Solutions Messages Manual
BMC153048S <product name> <componentname> processing not possible.
Explanation: The component <componentname> for the Application
Enhancement Solutions (AES) product <product name> is not available for
processing.
System Action: The component will not execute.
User Response: Refer to other messages surrounding this message for an indication
of the problem that generated this message.
BMC153050S Module <modulename> not located in any linklist library. <bcssid>
Explanation: The Application Enhancement Solutions (AES) product could not
locate a module in any library available to the job step execution. <modulename>
indicates the name of the module.
System Action: AES product initialization continues without the module
<modulename>.
User Response: Place the module in a library available to the job step execution,
and issue the bcssid REINIT <product name> command to reinitialize.
BMC153052S Load of <modulename> into the private area failed, R15<returncode>.
<bcssid>
Explanation: A request to load a module into the private area of the subsystem
address space has failed. <modulename> indicates the name of the module.
<returncode> indicates that the return code passed to register 15.
System Action: Application Enhancement Solutions (AES) product initialization
continues, but the module is not loaded until you resolve the problem.
User Response: Increase the REGION parameter specified for the BMCBCSS
procedure to at least 4096 KB (4 MB); then stop and restart the subsystem. If the
problem continues, contact BMC Software Product Support.
BMC153054S Insufficient common storage available to load <modulename>.
<bcssid>
Explanation: Not enough storage was available in the common service area
(CSA) to contain a module. <modulename> indicates the name of the module. The
attempted storage allocation was for 24-bit addressable storage in subpool 241.
System Action: Application Enhancement Solutions (AES) product initialization
continues, but the module <modulename> is not loaded until you resolve the
problem.
User Response: Increase the amount of CSA storage available in your system; then
stop and restart the subsystem. If the problem continues, contact BMC Software