A SERVICE OF

logo

Cause Corrective Action
The test pattern was printed too faintly. Take steps to remedy faint printing.
(See "Printing is faint.") →P.954
Direct sunlight or strong lighting may be shin-
ing on the printer and causing the sensor to
malfunction.
Press the OK button to clear the error.
Take steps to ensure the printer is not used when exposed to direct
sunlight or strong lighting.
Excessive temperature or humidity.
Cause Corrective Action
The temperature or humidity where
the printer is installed is out of the
acceptable range for operation.
Press or to select Stop, and then press the OK button to stop printing.
Use the printer under suitable environmental conditions. Also note that various
environmental conditions are recommended for various types of paper. For de-
tails on the recommended environmental conditions, see the Paper Reference
Guide.
(See "Types of Paper.") →P.712
Press or to select Continue, and then press the OK button to continue
with color calibration. However, note that correct adjustment may not be possi-
ble.
Before borderless printing, move the blue platen switch.
Cause Corrective Action
The blue Switch on the platen was set to the side
opposite ● when a borderless print job was re-
ceived.
Before borderless printing, set the blue Switch on the platen to
the ● side.
(See "Setting the Blue Switch on the Platen.") →P.961
Blue platen switch is dirty.
Cause Corrective Action
The blue Switch on the platen is dirty. Open the Top Cover and clean the blue Switch on the platen.
(See "Cleaning Inside the Top Cover.") →P.927
Move the blue platen switch No.xx to the right. (xx represents a number)
Cause Corrective Action
The printer has detected that the blue Switch on the plat-
en needed in maintenance during printing is set away
from the ● mark.
Set blue platen Switch of the indicated number toward the ●
side.
(See "Setting the Blue Switch on the Platen.") →P.961
Error Message
>
Messages regarding printing or adjustment
>
iPF6300 Excessive temperature or humidity.
12