66 ESL E-Series Tape Library User’s Guide
Restore Factory Setting
Drive Autoclean
Configured Drives
Left Load Port (18)
Right Load Port (36)
3. To edit the setup information, use the up and down arrows to highlight the
section and press
Select.
To set the IP address, subnet mask, and gateway, use the up and down
arrows to select the appropriate number and press
Select to accept.
To enable/disable DHCP, use the up and down arrows to toggle between
enable/disable. Press
Select to accept the setting. If your library is not
connected to a network that uses a DHCP server to assign IP information,
disable this function.
To change the password, use the up and down arrows to select Change
Password and press
Select. To change the password, enter a 6-digit
password using the numbers provided on the OCP. Press
Select to accept
the new password. When prompted, re-enter the password to confirm.
To enable autoclean, use the up and down arrows to select Autoclean and
press
Select. The default is disabled.
To configure the number of tape drives in the cabinet, use the up and
down arrows to select the number of drives and press
Select.
Caution: If you have a partially filled drive cluster, change the number of tape
drives to reflect the number of installed drives. For example, a cluster with two
drives will show as four drives total with two being inactive. Use the Setup
menu to change Configured Drives to 2 instead of 24, which is the default. This
helps avoid potential issues with your application software.
To enable the left load port, use the up and down arrows to select Left
Load Port (18) for Ultrium libraries or Left Load Port (16) for SDLT
libraries, then press
Select. The default is disabled.
To enable the right load port, use the up and down arrows to select Right
Load Port (36) for Ultrium libraries and Right Load Port (32) for SDLT
libraries, then press
Select. The default is disabled.