A SERVICE OF

logo

2.5 Manual Override
The Manual Override is provided to allow the GLK24064-25 to be reset to factory defaults. This can be
particularly helpful if the display module has been set to an unknown baud rate or I
2
C Slave Address and
you are no longer able to communicate with it. If you wish to return the module to its default settings you
must:
1. Power off the display module.
2. Place a Jumper on the Manual Override pins 1 and 2 as pictured below.
3. Power up the display module.
4. The display module is now set to its default values listed below in table 2.
5. Edit and save settings.
Figure 18: Manual Override Jumper
Table 2: Default Values
Contrast 128
Backlight 255
Baud Rate 19.2 kbps
I
2
C Slave Address 0x50
Data Lock False
RS232AutoTransmitData True
NOTE The display module will revert back to the old settings once turned off, unless the
settings are saved.