A SERVICE OF

logo

Remembered Always
Factory Default 0x50
4.6 Setting a Non-Standard Baud Rate
Syntax
Hexadecimal 0xFE 0xA4 [speed]
Decimal 254 164 [speed]
Parameters
Parameter Length Description
speed 2 Inputed LSB MSB from baud rate
formula (12-2047).
Description This command sets the RS-232 port to a non-standard baud rate. The
command accepts a two byte parameter that goes directly into the mod-
ules baud generator. Use the formula, speed =
16,000,000
8×DesiredBaud
1 to cal-
culate the [speed] for any baud rate setting. The speed can be anywhere
from 12 to 2047 which corresponds to a baud range of 977 to 153,800
baud. Setting the baud rate out of this range could cause the display to
stop working properly and require the Manual Override jumper to be set.
Remembered Always
Examples
speed =
16,000,000
8×DesiredBaud
1
speed =
16,000,000
8×115,000
1
speed = 17.3911
speed = 16.391
LSB = 16
MSB = 0
NOTE Results from the formula are rounded to the nearest whole number.