A SERVICE OF

logo

6 - 10
Chapter 6 Sequence Program Used for Positioning Control
Device
name
Device
Application Details of storage
Axis 1 Axis 2 Axis 3 Axis 4
Data register
D15
Acceleration time setting
(low-order 16 bits)
[Cd.10] New acceleration time value
D16
Acceleration time setting
(high-order 16 bits)
D17
Deceleration time setting
(low-order 16 bits)
[Cd.11] New deceleration time value
D18
Deceleration time setting
(high-order 16 bits)
D19
Acceleration/deceleration time change
enable
[Cd.12] Acceleration/deceleration
time change during speed
change, enable/disable
selection
D20 Step mode [Cd.34] Step mode
D21 Step valid flag [Cd.35] Step valid flag
D22 Step start information
D23 Target position (low-order 16 bits)
[Cd.27] Target position change value
(New address)
D24 Target position (high-order 16 bits)
D25 Target speed (low-order 16 bits)
[Cd.28] Target position change value
(New speed)
D26 Target speed (high-order 16 bits)
D27 Target position change request
[Cd.29] Target position change
request flag
D30 ZP.PSTRT1 instruction control data
D31 Completion status
D32 Start number
D33 ZP.TEACH1 instruction control data
D34 Completion status
D35 Teaching data
D36 Positioning data No.
D37 ZP.PINIT instruction control data
D38 Completion status
D39 ZP.PFWRT instruction control data
D40 Completion status
D50 Unit setting [Pr.1] Unit setting
D51 Unit magnification [Pr.4] Unit magnification (AM)