![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/c/c5/cc53ae9d-9823-41c4-bec9-cfc5760f18ed/cc53ae9d-9823-41c4-bec9-cfc5760f18ed-bg29.png)
IES-1000 Hardware Installation Guide
Appendix A Removing and Installing a Fuse A
Appendix A
Removing and Installing a Fuse
This appendix shows you how to remove and install fuses for the IES-1000.
The IES-1000 uses one 250V-3A fuse. The IES-1000 comes with two 250V-3A fuses; one is installed at the
factory (in the fuse housing) and the other is a spare (also located inside the fuse housing). If you need to install a
new fuse, follow the procedure below.
Before you begin, you will need:
• A small flat head screwdriver
• A 250V 3A fuse
• Good lighting
Removing and Installing Fuses
Removing Fuses
Safety first! Disconnect all power from the IES-1000 before you begin this procedure.
Step 1. Place the front panel of the IES-1000 in front of you.
Step 2. Remove the power cord from the back of the unit for easy access to the fuse housing as shown next.
Diagram 1 Removing the Power Cord