![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/5/96/5967e40c-9b71-1494-7db8-c0a37d8d3d18/5967e40c-9b71-1494-7db8-c0a37d8d3d18-bga0.png)
Total Access 1248 Octal T1 IMA DSLAM Installation and Maintenance Practice
5-108 61179641L4-5B
The E1 Performance Monitoring Status screen hot keys are defined in Table 5-74.
CV-P Code Violations This code indicates an occurrence of either a CRC-6
error or frame bit error on the path.
CV-L Code Violations This code indicates an occurrence of either a CRC-6
error or frame bit error on the line.
ES-L Errored Seconds This code indicates seconds with either a bipolar
violation or a CRC-6 error on the line.
Table 5-74. E1 Performance Monitoring Status Screen Hot Keys
Hot Key Description Function
B
Backward(2hrs/15min PM) This hot key is used to display performance monitoring
statistics for the last 2 hours, in 15 minute intervals.
C
Clear PM Stats This hot key is used to clear the performance monitoring
statistics.
F
Forward(2hrs/15min PM) This hot key is used to display performance monitoring
statistics for the next 2 hours, in 15 minute intervals.
N
Next Port This hot key is used to display the next port.
P
Previous Port This hot key is used to display the previous port.
S
Select Port This hot key is used to select a specific port.
Table 5-73. E1 Performance Monitoring Status Screen Codes (Continued)
Code Definition Description