A SERVICE OF

logo

61223424L2-5A Issue 1, December 2003 9
The Provisioning menu (Figure 8) displays current
provisioning settings for the HDSL4 circuit. Options
that can be changed from this screen are labeled with a
number (for example, “1” for DSX-1 Line Build Out).
To change a particular option setting, select the appro-
priate number, and a new menu will appear with a list of
the available settings.
The options shown in Table 5 are available with the
T200 H4TU-R (P/N 1223426L2). Some settings may
differ when using different H4TU-Rs.
The
Span Status Screen (Figure 9) provides quick
access to status information for each HDSL4 receiver in
the circuit.
Figure 8. Provisioning Menu
Figure 9. Span Status Screen
Circuit ID: 10/01/03 09:29:45
Press ESC to return to previous menu
Provisioning
1. DSX-1 Line Buildout = 0-133 ft
2. DSX-1/DS1 Line Code = B8ZS
3. DSX-1/DS1 Framing = ESF
4. Forced Frame Conversion = Disabled
5. Smartjack Loopback = Enabled
6. Loopback Timeout = 120 Min
7. Latching Loopback Mode = T1 (Disabled)
8. DS1 TX Level = 0 dB
9. Span Power = Enabled
10. Customer Loss Indicator = AIS/CI
11. PRM Setting = AUTO
12. Loop Atten Alarm Thres = 34dB
13. SNR Margin Alarm Thres = 04dB
14. Remote Provisioning = Enabled
D. Restore Factory Defaults
Selection:
Circuit ID: 10/01/03 09:29:45
Press ESC to return to previous menu
Span Status Screen
______ ______ ______ ______
NET | | | | | | | | CUST
| | | | | | | |
----->| |-------| |-------| |----------------------| |----->
| | | | | | | |
| | | | | | | |
<-----| |-------| |-------| |----------------------| |<-----
| | | | | | | |
DSX-1 |______| |______| |______| |______| DS1
H4TUC H4R 1 H4R 2 H4TUR
1. View Detailed Status
Selection: