Rx100 installation manual V1.17 29 Aug 08.doc Page 13
BBV Rx100/24 Supply Additional information (iss. 6 pcb)
The RX100/24 can be powered from either 230Vac or 24Vac. The diagrams below shows the connections that
should be made for each supply voltage. Please note that when powered from 24Vac the 230Vac terminals will be
at mains voltages. To prevent the risk of shocks the fuse must be removed from the fuse holder and no connections
made to L and N. The 24Vac supply must be fused with a 315mA to protect the supply wiring.
Fig 9. RX100/24 iss. 6 pcb Connection details when operating from a 230Vac supply.
Important! When
operating the unit
from 24Vac, the fuse
from the 230Vac
connector fuse holder
must be removed. No
connections must be
made to this connector,
as it will have 230Vac
across the L & N
terminals.
Fig 10. RX100/24 iss. 6 pcb Connection details when operating from a 24Vac supply.
IMPORTANT! Remove fuse from fuseholder
and make no connection as these terminals
will have 230Vac across L and N.
24Vac
Supply
!
315mA Fuse
24Vac 100VA
output to power dome
230Vac Supply