3. INSTALLATION
OPERATING VOLTAGE
The Rx100 requires all connections to the PCB to be made by the installer, and via terminal blocks or by plug
and socket. These connections are: power in, video in, video out, and serial data to dome. In addition
connections for alarm in, alarm out and lights if required are provided. See fig.2 below for correct connections.
The Rx100 is supplied pre-configured to suit the application for which it is intended, i.e. to control an integrated
dome camera.
IMPORTANT NOTE – If link J6/4-5 is removed it must be refitted to J6/3-4 position or the RX100 will
assume it is still fitted.
Fig. 2 Rx100 Iss6 PCB connections
J3
AC
AC
TP
TP
GND
C1
C2
C3
C4
GND
AOUT
AOUT
GND
GND
A1
A2
A3
A4
J3
J4
J7
9-12V
supply
N/C
Alarm
contacts IN
POWER 9 - 12 V AC/DC
100mA MAX
BBV
RY1
4 Amp 250V MAX
J5
TELEMETRY
CAMERA
GAINLIFT
J6 OPTION LINKS
Video In
from dome
Video Out
to transmitter
SW LIVE EARTH NEUTRAL
Lights Supply
Lights
Feed
Neutral
Earth
Live
HF Lift Gain
www.bbvcctv.com
pcb 97002 Iss 6
Test
J6/1-2
1
5
J6/4-5
CABLE
ERROR
J1
RS485 OUT to dome
N/C Alarm
OUT
Twisted Pair IN from
telem transmitter
Test LinkRS485 to Panasonic domes
Function Connector Type
Power In J4 2.1mm coaxial
or J3/AC-AC Grey WAGO
Video In CAMERA BNC SOCKET
Video Out TELEMETRY BNC SOCKET
Twisted Pair Telemetry J3/TP-TP Grey WAGO
Serial to dome J3/C1-C4-GND Grey WAGO
or J7 FCC68 (Fitted for Panasonic versions)
Alarm 1 contact in J3/A1-GND Grey WAGO (optional if alarm input required)
Alarm 2 contact in J3/A2-GND Grey WAGO (optional if alarm input required)
Alarm 3 contact in J3/A3-GND Grey WAGO (optional if alarm input required)
Alarm 4 contact in J3/A4-GND Grey WAGO (optional if alarm input required)
Alarm contact out J3/AOUT-AOUT Grey WAGO (optional if alarm input required)
Lighting relay J5 Coloured WAGO (optional if lights control required)
(clean contact between orange connectors)