A SERVICE OF

logo

TROUBLESHOOTING
Error Codes
The Model 225 indicator is equipped with software that indicates when an error in the
operation takes place. The following lists the error codes displayed by the 225 along with their
, please refer to this list for the cause.
¤ ¤ ¤ ¤
d range of the indicator.
meaning. Should you encounter an error code
ANALOG HIGH
¤ ¤ ¤
1. The load cell input is above the allowe
UCORRECTIVE ACTIONU: Check for imprope
output of 1 to 40mV.
Load cell or circuit failure.
r load cell wiring, excessive load, and for
2.
UCORRECTIVE ACTIONU: Consult your scale
service provider.
1. The load cell input is below the allowed range of the ind
N
ANALOG LOW
¤ ¤ ¤ ¤ ¤ ¤ ¤
icator.
UCORRECTIVE ACTIO U: Check for improper load cell wiring and for output of 1 to 40mV.
2. Load cell or circuit failure.
UCORRECTIVE ACTIONU: Consult your scale service provider.
lus 9
UCORRECTIVE ACTION
OVERCAP
¤ ¤ ¤ ¤ ¤ ¤ ¤
The load on the scale exceeds the scale capacity (105% of capacity if USA=YES or p
divisions if USA=NO). May indicate miscalibration.
U: Remove the over capacity load from the scale platform. Consult
your scale service provider regarding recalibration.
CHECK MATL
In a Digital Fill Control or Batcher operation configured for decumulative operation
(ACCUMLATE=YES) there is not enough material to start the operation.
UCORRECTIVE ACTIONU: Determine the reason for the error display and take the
appropriate corrective action.
CHECK ZERO
In a Digital Fill Control or Batcher operation with DUMP GATE=YES and AUTO
TARE=NO the weight is above the zero tolerance value.
UCORRECTIVE ACTIONU: Determine the reason for the error display and take the
appropriate corrective action.
8200-M538-O1 y 225 Installation
Page 103