Chapter 3. Operation T1 ESF CSU ACE User Manual
48 © 2004 ADTRAN, Inc 61204025L1-1B
6)REMOTE T-WATCH, Submenu of 3)UTIL
To communicate with a far-end unit via the FDL (i.e., from a proxy such as T-Watch), identify the
remote unit as a standalone or rackmount. Use this option to select the remote unit type, ID, and slot
number. The ID and slot number are only applicable if the selected remote unit is rackmount, so these
may be left blank if the remote unit is standalone.
1)ACCESS TYPE (REMOTE UNIT)
1)STANDALONE - The far-end unit is standalone.
2)RACKMOUNT - The far-end is a rackmount.
2)SHELF SNMP ID
Enter the SNMP ID of the far-end rackmount unit (0-255).
3)SHELF SLOT
Enter the slot number of the far-end rackmount unit (1-16).
4)TEST
Use the Test menu to initiate different types of tests of the unit and view test results. The menu
contains four sub-items. See Figure 3-19.
Figure 3-19. Test Menu Tree
This type of communication may not be available with all T1 products.
The execution of tests disrupts some of the normal operation. See individual menu items
concerning tests before executing.
NO LOOPBACK
1)LOCAL LOOPBK DTE ON
LINE ON NO LOOPBACK
PAYLOAD ON AT&T INBAND LLB
ANSI FDL LLB
2)REM LB AT&T FDL PLB
4)TEST NO PATTERN
ALL ZEROS
3)TEST PATTERN 1:8 ALL DS0s
ALL ONES
4)RUN SELFTEST