A SERVICE OF

logo

17.3
17
Technical data K 1100 LT K 1100 RS
Cooling system capacity l(Imp.gal) 3.0 (0.66)
+ 0.4 (0.088)
in expansion tank
Coolant
Antifreeze
Water
%
%
Concentration (down to - 28 °C)
40
60
Only use nitride-free long-term frost and corro-
sion protection agents
Thermostat opens at
°C 85
Cut-in temperature for fan °C 105
Cut-in temperature for coolant warning lamp °C 115
Pressure relief valve in cap opens at bar (psi) 1.0 = 120 °C (14.504 = 120 °C)
Vacuum valve in cap opens at bar (pis) - 0.1 (-1.4504)