A SERVICE OF

logo

Communications
4-51
Printer Configuration
Spooling Timeout
Sets the number of seconds the interface waits for data from the host
before terminating a spooled print job.
Data Bits
Sets the number of data bits transmitted per character.
End Job Mode
Enables (and identifies an end-of-job sequence) or disables data
stream sensing for the end-of-document (EOD) command.
Menu
Administration/Communications/Parallel/Spool
Timeout
Choices
00000-99999
Default
00030
Menu
Administration/Communications/Parallel/Data Bits
Choices
7, 8
Default
8
Menu
Administration/Communications/Parallel/End Job
Mode
Choices
None—The printer recognizes only the PostScript ^D
command.
QMS EOD—The printer recognizes only the QMS
%%EndOfDocument command.
HP EOD—The printer recognizes only the HP
<ESC>%12345X command.