A SERVICE OF

logo

Additional Conferencing Information
Polycom®, Inc. 181
3 In the Channel Info field, select Audio In or Audio Out to display the audio parameters.
4 Click the OK button.
Automatic Muting of Noisy Endpoints
The automatic muting of noisy AVC-enabled endpoints can be used according to the following guidelines:
The Auto mute noisy endpoints check box in the Profile Properties - Audio Settings dialog box is
enabled only when the ENABLE_SELECTIVE_MIXING flag is set to YES (default).
It affects only AVC-based and audio only endpoints (non-SAC endpoints)
It does not affect SVC-based endpoints
It is supported in CP conferences and in Mixed CP and SVC conferences.
In a mixed CP and SVC conferences, only the AVC-based endpoints can be automatically muted. If
the noisy endpoint is SVC-based, its audio channel will not be sent to the AVC-based endpoints, but
it will be sent to the other SVC-based endpoints.
MCU reset is not required when changing the ENABLE_SELECTIVE_MIXING flag setting.
When upgrading from a version prior to 8.1, the Auto mute noisy endpoints option is not automatically
enabled in the existing Profiles and it has to be manually enabled, if required.