4 – Managing Switches
Displaying Switch Information
59022-06 A 4-9
Q
FC-SW-2 Compliant Zoning merge status. If True, changes to the active zone
set are propagated throughout the fabric. If false, changes
to the zoning database are propagated throughout the
fabric.
LegacyAddressFormat Legacy port addressing status. Enabled only for
interoperability with non-FC-SW-2 switches.
FC-SW-2 Auto Save Zoning auto save status. Saves zoning updates in
temporary and permanent memory (True) or only in
temporary memory (False).
Zoning Default Visibility Zoning visibility status. Permits (All) or prevents (None)
communication with other switches in the absence of an
active zone set.
Temperature Internal switch temperature °C
Fan 1 Status Fan 1 status
Fan 2 Status Fan 2 status (SANbox2-16 only)
Fan 3 Status Fan 3 status (SANbox2-16 only)
Power Supply 1 Status Power supply 1 status
Power Supply 2 Status Power supply 2 status (SANbox2-16 only)
Beacon Status Beacon status. Switch LEDs are blinking (On) or not (off).
Broadcast Support Broadcast support status. Broadcast support is enabled or
disabled (default).
Inband Enabled Inband management status. Permits (True) or prevents
(False) a switch from being managed over an ISL.
Temp Failure Port
Shutdown
Port shutdown status. If True, all ports are downed when
the switch temperature exceeds the Failure Temperature.
If False, port operational states remain unchanged.
Warning Temperature Warning temperature threshold in °C above which a
warning condition alarm is generated.
Failure Temperature Failure temperature threshold in °C above which a failure
condition alarm is generated.
Table 4-3. Switch Data Window Entries (Continued)
Entry Description