A SERVICE OF

logo

ZQ110
Rev. 1.00
- 41 -
Mobile Printer Command Manual
<Function 065> GS ( k pL pH cn fn n (fn=65)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
30
41
n
Decimal
29
40
107
3
0
48
65
n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48, fn=65
0 ≤ n ≤ 30
n=0
Specifies the number of columns of the data area of PDF417.
- n=0 specifies auto processing
- When n is not 0, specifies the number of columns of the data area as
n code word.
Settings of this function affect the processing of Functions 081.
When auto processing (n=0) is specified, the maximum number of
columns in the data area is 30 columns.
The following data is not included in the number of columns :
- Start pattern and stop pattern
- Indicator code word of left and right
When auto processing (n=0) is specified, the number of columns is
calculated by the printing area when processing Functions 081 module
width (Function 067), and option setting (Function 070).
This function is effective until ESC @ is executed, the printer is reset, or
the power is turned off.
<Function 066> GS ( k pL pH cn fn n (fn=66)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
30
42
n
Decimal
29
40
107
3
0
48
66
n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48, fn=66
n=0, 3 ≤ n ≤ 90
n=0
Specifies the number of rows of data area of PDF417.
- n=0 specifies auto processing
- When n is not 0, specifies the number of rows of the symbol as n rows.
Settings of this function effect the processing of Functions 081.
When auto processing (n=0) is specified, the maximum number of rows is 90.
When auto processing (n=0) is specified, the number of rows is calculated
by the printing area when processing Functions 081 module height
(Function 068).
This function is effective until ESC @ is executed, the printer is