A SERVICE OF

logo

ZQ110
Rev. 1.00
- 52 -
Mobile Printer Command Manual
Output:
<Function 465> GS ( k pL pH cn fn n (fn=65)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
34
41
n
Decimal
29
40
107
3
0
52
65
n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=52
fn=65
50<=n<=60
n=50
Selects the GS1 Databar.
n
Function
50
RSS14 (GS1 DataBar Omnidirectional)
51
RSS14 Truncated (GS1 DataBar Truncated)
52
RSS14 Stacked (GS1 DataBar Stacked)
53
RSS14 Stacked Omnidirectional (GS1
DataBar Stacked Omnidirectional)
56
UPC-A
57
UPC-E
58
EAN-13
59
EAN-8
60
UCC/EAN-128&CC-A/B
61
UCC/EAN-128&CC-C
The setting of this command affects <Function 480> and <Function 481>
The setting of this command remains effective until ESC @, printer reset
or power cycling is executed.