A SERVICE OF

logo

ZQ110
Rev. 1.00
- 53 -
Mobile Printer Command Manual
<Function 466> GS ( k pL pH cn fn n (fn=66)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII
GS
(
k
pL
pH
cn
fn
n1
n2
Hex
1D
28
6B
03
00
34
42
n1
n2
Decimal
29
40
107
3
0
52
66
n1
n2
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=52
fn=66
1<=n1<=8, 1<=n2<=8
n1=2
n2=2
Set the size of .the GS1 DataBar module height to n1, width to n2 dots.
The setting of this command affects <Function 480> and <Function 481>
The setting of this command remains effective until Esc @, printer reset
or power cycling is executed.
<Function 468> GS ( k pL pH cn fn n (fn=68)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
34
44
n
Decimal
29
40
107
3
0
52
68
n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=52
fn=68
1<=n<=255
n=32
Set the module segment height of UCC/EAN-128 barcode type.
This settings will be effective only UCC/EAN-128 barcode type.
The setting of this command affects <Function 480> and <Function 481>
The setting of this command remains effective until ESC @, printer reset
or power cycling is executed.