A SERVICE OF

logo

Chapter 11: Troubleshooting
137
Upon reset, you will see the following messages on the LCD and the system will halt:
“First row test”
“0064 MB”
“ALL DIMM MAP OUT”
User Action
1. Determine the first row of DIMMs using the scanning order defined in Table 11-2. Replace
the first row of DIMMs with known good DIMMs. On replacing the DIMMs, make sure the
size and HP part number match.
2. Clear CMOS via the front panel or via clear CMOS jumper in order to clear previous defective
DIMM history.
3. Power on the system.
NOTE: The defective rows of DIMM found during base memory test can be determined
once the system boots from the “DIMMs mapped out” message. Then, those
DIMMs can be replaced, if needed.
Error Logging
The defective row/DIMM(s) found during the base memory test will be logged to the SEL. This
includes both single-bit errors (SBE) and multi-bit errors (MBE).