If any LEDs are flashing, you held the Set button down too long. Holding down the Set button for 3
seconds places KeypadLinc into Programming Mode.
Programming Mode will time out after 4 minutes of inactivity. To manually exit Programming Mode, tap
the On button.
Using the Air Gap
Pulling the Set button at the bottom of the paddle out as far as it will go (about
1
/
8
inch) opens mechanical
contacts that remove all power from KeypadLinc and the load that it controls. “Air gapping” can be useful
for replacing bulbs or any other time you want the controlled circuit to be unpowered.
Because the KeypadLinc settings are stored in non-volatile memory, setup information will not be lost
when the device unpowered.
ON-LEVELS AND RAMP RATES (KeypadLinc Dimmer only)
About On-Levels and Ramp Rates
The On-Level is the brightness that the load will go to when you turn it on. The On-Level is adjustable
from off to 100% brightness. The default is 100%.
The Ramp Rate is the amount of time it will take the load to go from full-off to full-on or from full-on to full-
off. The Ramp Rate is adjustable from 0.1 to 9 seconds to ramp between full-on and full-off and vice
versa. The default is 0.1 seconds.
You can set up a local On-Level/Ramp Rate for the load, which is activated by tapping the On/Off buttons
on KeypadLinc. Or set up remote On-Levels/Ramp Rates that are activated when you tap and On/Off or
Scene button on a Linked Controller. A single KeypadLinc is capable of storing different On-Levels and
Ramp Rates for each Linked Controller (or each button if it is a multi-scene Controller).
On-Levels and Ramp Rates are locked in separately and can be set up in any order. When you do the
lock-in, the most recently set On-Level and Ramp Rate are locked in together.
Setting the On-Level on KeypadLinc Dimmer
1) Use the On and Off buttons on KeypadLinc to adjust the light to the desired brightness
2) Once the desired brightness has been achieved, tap the Set button on KeypadLinc
KeypadLinc will beep
3) Test the On-Level settings by tapping the On/Off buttons on KeypadLinc
KeypadLinc will respond appropriately
The local On-Level has now been set. If you would like to set up a Controller to set KeypadLinc to the
programmed On-Level, proceed to Linking an INSTEON Controller to KeypadLinc Schedule Timer and
begin from step 2.
BE CAREFUL
If you press the Set button in too far when you undo the air gap, you might inadvertently reset
KeypadLinc to its factory default settings. Make sure to only push the Set button in until its top is flush