![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/4/95/495e4989-2b64-43a8-bf76-1deaf0b71432/495e4989-2b64-43a8-bf76-1deaf0b71432-bgcd.png)
A – Command Line Interface
Firmware Install Command
59097-02 B A-25
A
Firmware Install Command
Downloads firmware from a remote host to the switch, installs the firmware, then
resets the switch (without a power-on self test) to activate the firmware. This reset
is disruptive. To perform a non-disruptive firmware installation, refer to the ”Image
Command” on page A-38.
The command prompts you for the following:
IP address of the remote host
An account name and password on the remote host
Pathname for the firmware image file
Authority Admin
Syntax firmware install
Examples The following is an example of the Firmware Install command:
SANbox xxxx (admin) #> firmware install
Warning: Installing new firmware requires a switch reset.
Continuing with this action will terminate all management sessions,
including any Telnet sessions. When the firmware activation is complete,
you may log in to the switch again.
Do you want to continue? [y/n]: y
Press 'q' and the ENTER key to abort this command.
User Account : johndoe
IP Address : 10.20.33.130
Source Filename : 5.0.00.11_mpc
About to install image. Do you want to continue? [y/n] y
Connected to 10.20.33.130 (10.20.33.130).
220 localhost.localdomain FTP server (Version wu-2.6.1-18) ready.
331 Password required for johndoe.
Password: xxxxxxxxx
230 User johndoe logged in.
bin
200 Type set to I.
verbose
Verbose mode off.
This may take several seconds...
The switch will now reset.
Connection closed by foreign host.