330
350C
Media Type
Replot
Print Quality
Form Feed
Roll/Sheet
Continue
Plotting
8Ć55 TroubleshootingC4699Ć90000
Clearing the EEROM for the DesignJet 330 and 350C
If you clear the calibration parameters, you will then need to perform the plotter
calibrations. (Details ' chapter 7.) Clearing the EEROM also resets the factory
spittoon value to 0% used. Keep in mind that the value printed on the service
configuration plot may greatly underestimate the amount of ink in the spittoon.
CAUTION
Clearing Just the Benchrun and Calibration Parameters
1 Switch the plotter off.
2 While holding both the
Replot and Media Type keys down,
switch the plotter on.
3 Once the the LEDs begin to light up one by one, release the
Replot and Media Type keys.
Clearing Just the UserĆDefined Setup Parameters
1 Switch the plotter off.
2 While holding both the
Form Feed and Print Quality keys
down, switch the plotter on.
3 Once the the LEDs begin to light up one by one, release the
Form Feed and Print Quality keys.
Clearing All Parameters
1 Switch the plotter off.
2 While holding both the
Roll/Sheet and Continue Plotting
keys down, switch the plotter on.
3 Once the the LEDs begin to light up one by one, release the
Roll/Sheet and Continue Plotting keys.