Cumberland Gap Wood Stove
7006-188G
D. Chimney Termination Requirements
Follow manufacturer’s instructions for clearance, securing
ashing and terminating the chimney.
Must have an approved and Listed cap
Must not be located where it will become plugged
by snow or other material
Must terminate at least 3 feet (91cm) above the
roof and at least 2 feet (61cm) above any portion
of the roof within 10 feet (305cm).
Must be located away from trees or other struc-
tures
These are safety requirements and are not meant to assure proper ue draft.
Figure 22.1
E. 2-10-3 Rule
Figure 22.2
NOTE:
Chimney performance may vary.
Trees, buildings, roof lines and wind conditions affect
performance.
Chimney height may need adjustment if smoking or
overdraft occurs.
3 ft. (91cm)
Minimum
Less than 10 ft. (305cm)
2 ft. (61cm)
3 ft. (91cm)
Minimum
10 ft. (305cm) To Nearest Roofline
2 ft. (61cm)
Pitched Roof
10 ft. (305cm) or more
3 ft. (91cm) Minimum
Less than 10 ft. (305cm)
2 ft. (61cm)Minimum
3 ft. (91cm) Minimum
Wall or Parapet
Flat Roof