R
Page 4
November 5, 2010
Cumberland Gap Wood Stove
7006-188G
The Quadra-Fire Yosemite Wood Stove meets the U.S.
Environmental Protection Agency’s 1990 particulate emis-
sion standards.
A. Appliance Certifi cation
C. Glass Specifi cations
D. BTU & Effi ciency Specifi cations
This stove is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
EPA Certifi ed:
3.44 grams per hour
Effi ciency:
79.3%
BTU Output:
11,200 to 44,300
Heating Capacity:
1,940 to 3,350 sq ft
depending on climate zone
Vent Size:
6 inches
Firebox Size:
2.39 cubic feet
Max Wood Length:
20 inches
Fuel:
Cord Wood
Shipping Weight:
462 lbs
Model:
Cumberland Gap
Laboratory: OMNI Test Laboratories, Inc.
Report No & Date:
061-S-55-2
Type:
Listed Room Heater, Solid Fuel Type
Standard: UL1482, UL737, ULC S627-00
and (UM) 84-HUD, Mobile Home
Approved.
NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the UL1482, UL737,
(UM) 84-HUD and NPFA211 in the U.S.A. and the ULC S627-00
and CAN/CSA-B365 Installation Codes in Canada.
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products,
their specifi cations and/or price without notice.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualifi ed
installer, service agency or your dealer.
Quadra-Fire is a registered trademark of Hearth & Home
Technologies.
• Installation and use of any damaged appliance.
• Modifi cation of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not
approved by Hearth & Home Technologies.
• Operating appliance without fully assembling all
components.
• Operating appliance without legs attached (if supplied
with unit).
• Do NOT Overfi re - If appliance or chimney connector
glows, you are overfi ring.
Any such action that may cause a fi re hazard.
WARNING
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
B. Mobile Home Approved
• This appliance is approved for mobile home installa-
tions when not installed in a sleeping room and when
an outside combustion air inlet is provided.
• The structural integrity of the mobile home fl oor, ceil-
ing, and walls must be maintained.
• The appliance must be properly grounded to the frame
of the mobile home with #8 copper ground wire, and
use only listed double-wall connector pipe.
• Outside Air Kit, part 831-1780 must be installed in a
mobile home installation.
1
Listing and Code Approvals