A SERVICE OF

logo

R
Page 4
November 5, 2010
Cumberland Gap Wood Stove
7006-188G
The Quadra-Fire Yosemite Wood Stove meets the U.S.
Environmental Protection Agency’s 1990 particulate emis-
sion standards.
A. Appliance Certi cation
C. Glass Speci cations
D. BTU & Ef ciency Speci cations
This stove is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
EPA Certi ed:
3.44 grams per hour
Ef ciency:
79.3%
BTU Output:
11,200 to 44,300
Heating Capacity:
1,940 to 3,350 sq ft
depending on climate zone
Vent Size:
6 inches
Firebox Size:
2.39 cubic feet
Max Wood Length:
20 inches
Fuel:
Cord Wood
Shipping Weight:
462 lbs
Model:
Cumberland Gap
Laboratory: OMNI Test Laboratories, Inc.
Report No & Date:
061-S-55-2
Type:
Listed Room Heater, Solid Fuel Type
Standard: UL1482, UL737, ULC S627-00
and (UM) 84-HUD, Mobile Home
Approved.
NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the UL1482, UL737,
(UM) 84-HUD and NPFA211 in the U.S.A. and the ULC S627-00
and CAN/CSA-B365 Installation Codes in Canada.
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products,
their speci cations and/or price without notice.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a quali ed
installer, service agency or your dealer.
Quadra-Fire is a registered trademark of Hearth & Home
Technologies.
Installation and use of any damaged appliance.
• Modi cation of the appliance.
Installation other than as instructed by Hearth & Home
Technologies.
Installation and/or use of any component part not
approved by Hearth & Home Technologies.
Operating appliance without fully assembling all
components.
Operating appliance without legs attached (if supplied
with unit).
Do NOT Over re - If appliance or chimney connector
glows, you are over ring.
Any such action that may cause a re hazard.
WARNING
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
B. Mobile Home Approved
This appliance is approved for mobile home installa-
tions when not installed in a sleeping room and when
an outside combustion air inlet is provided.
The structural integrity of the mobile home oor, ceil-
ing, and walls must be maintained.
The appliance must be properly grounded to the frame
of the mobile home with #8 copper ground wire, and
use only listed double-wall connector pipe.
Outside Air Kit, part 831-1780 must be installed in a
mobile home installation.
1
Listing and Code Approvals