![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/e/9e/e9e80867-da89-4f28-b7db-f9f833b6dbfe/e9e80867-da89-4f28-b7db-f9f833b6dbfe-bgab.png)
B – Command Line Interface
Set Config Command
59043-03 A B-49
D
zoning
Initiates an editing session in which to change switch zoning attributes. The
system displays each parameter one line at a time and prompts you for a value.
For each parameter, enter a new value or press the Enter key to accept the
current value shown in brackets.
Examples The following is an example of the Set Config Blade command:
SANbox2-64 108 (admin-config) #> set config blade 1
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the default value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'qq' and the ENTER key to do so.
Configuring Blade in Slot Number: 1
---------------------------------
AdminState (1=Online, 2=Offline, 3=Diagnostics, 4=Down) [Online]
Finished configuring attributes.
This configuration must be saved (see config save command) and
activated (see config activate command) before it can take effect.
To discard this configuration use the config cancel command.
Table B-16. Set Config Zoning Parameters
Parameter Description
FC-SW-2 AutoSave Available only when the FC-SW-2
Compliant parameter is True, this
parameter enables (True) or disables
(False) the saving of changes to active
zone set in the switch’s permanent
memory. Refer to ”FC-SW-2 Compliant”
on page B-47. The default is True.
Default Visibility Enables (All) or disables (None)
communication among the switch’s
ports/devices and the fabric in the
absence of an active zone set. The
default is All.