CB 1200 Pellet Stove
*L Exception for Horizontal Installations:
USA INSTALLATIONS:A
non-combustibleoorprotec-
tion is recommended extending beneath the ue pipe
when installed with horizontalventing or under the top
ventadapterwithverticalinstallation.
CANADA INSTALLATIONS:A
non-combustible oor
protection extending beneath the ue pipe is required
withhorizontalventingorunderthetopventadapterwith
verticalinstallation.
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
C. Hearth Pad Requirements (UL and ULC)
L*
K
K
M
Useanon-combustibleoorprotector,extendingbeneath
appliance andto the front,sides andrear as indicated.
Measurefrontdistance“M”fromthesurfaceoftheglass
door.
Hearth Pad Requirements
Inches Millimeters
K
Sides 2 51
L*
Back 2 51
M
Front 6 152