CB 1200 Pellet Stove
Werecommendaminimumof60in.(1.5m)vertical,
howeverabovetheeaveispreferred.
Bothinstallationsareapprovedformobilehomeinstal-
lations.Mustuse3or4inch(76to102mm)“L”or
“PL”Listedpelletventingorlisteddoublewallpipeand
Quadra-Fireoutsideairkitinmobilehomes.Single
wallpipeisapprovedforresidentialinstallationsonly.
C. Vertical into Existing Class A Chimney
D. Through The Wall & Vertical - External
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
3 in. (76mm)
Min.
Clean-out
Cover
24 in. (610mm)
minimum
Ceiling Support
Class A Chimney
Connector Adapter
Top Vent Kit
Non-combustible Hearth Pad
Clean-out Cover
Tee
Wall Thimble
Support Bracket
every 60 in. (1524mm)
24 in. (610mm)
Minimum
Rain Cap
Flashing
2 in. (51mm) Minimum
6 in. (152mm)
Minimum
Figure 15.1
Figure 15.2
E. Vertical - Internal - Typical Installation
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
3 in. (76mm) Min.
24 in.
(610mm)
Minimum
3 in. to 3 in.
(76-76mm)
Top Vent Kit
Clean-out Cover
Figure 15.3