![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/7/0e/70ed62ca-3de7-4787-8921-b038d6776f26/70ed62ca-3de7-4787-8921-b038d6776f26-bg11.png)
R
December 16, 2011
7014-179D
Page17
CB 1200 Pellet Stove
6
Mobile Home
1. Anoutsideairinletmustbeprovidedforthecombustion
airandmustremainclearofleaves,debris,iceand/or
snow.Itmustbeunrestrictedwhiletheapplianceis
inusetopreventroomair starvationwhichcauses
smokespillage.Smokespillagecanalsosetoffsmoke
alarms.
2. Thecombustionair ductsystemmustbemadeof
metal.Itmustpermitzeroclearancetocombustible
constructionandpreventmaterialfromdroppinginto
theinletorintotheareabeneath thedwellingand
containarodentscreen.
3. Theappliancemustbesecuredtothemobilehome
structurebyboltingittotheoor(usinglagbolts)intwo
places.Usethesameholesthatsecuredtheappliance
totheshippingpallet.
4. Theappliancemustbegroundedwith#8solidcopper
groundingwireorequivalent,terminatedateachend
withanNECapprovedgroundingdevice.
5. RefertoClearancestoCombustiblesandoorpro-
tectionrequirementsonpages 9& 10forlistingsto
combustiblesandappropriatechimneysystems.
6. Use siliconeto createaneffectivevaporbarrierat
thelocationwherethechimneyorothercomponent
penetratestothetheexteriorofthestructure.
7. Followthechimneymanufacturer’sinstructionswhen
installingtheventsystemforuseinamobilehome.
8. InstallationshallbeinaccordancewiththeManufactur-
ersHome&SafetyStandard(HUD)CFR3280,Part
24.
CAUTION
THE STRUCTURAL INTEGRITY OF THE MANUFAC-
TURED HOME FLOOR, WALL AND CEILING/ROOF MUST
BE MAINTAINED.
DoNOTcutthrough:
• Floorjoist,wall,studsorceilingtrusses.
• Anysupportingmaterialthatwouldaffectthestructural
integrity.
NEVER INSTALL IN A SLEEPING ROOM.
WARNING
InstallationmustcomplywithManufacturedHomeand
SafetyStandard(HUD),CFR3280,Part24.
WARNING
You must use a Quadra-Fire Outside Air Kit
for installation in a mobile home.
A. Mobile Home Installation
Figure 17.1
CAUTION
Neverdrawoutsidecombustionairfrom:
• Wall,oororceilingcavity
• Enclosedspacesuchasanatticorgarage
Spark Arrestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop
“PL” Pellet Vent