Troubleshooting116
305B Diag Fetch, Drive not loaded
(Diag: no cartridge present for fetch.)
• Press the Enter button to clear the
message.
• Load a cartridge in the drive and retry
the operation.
• Invalid user initiated operation. Set
parameters correctly and try again.
305D Diag Timeout waiting for drive empty,
ready
(Fetch, time-out waiting for drive unload.)
• Press the Enter button to reboot.
• Invalid user initiated operation. Set
parameters correctly and try again.
• Ensure the drive shows good status
through the drive status window.
• Check the tape cartridge used in the last
operation for damage.
305F Invalid bin number
(Invalid bin number detected in diag.)
• Press the Enter button to clear the
message.
• Invalid user initiated operation. Set
parameters correctly and try again.
3060 Zone Sequence Error
(Robot did not find sensor on power-up.)
• Cycle power to the library or reboot
using the GUI touch screen.
3074 Drive 0 Eject Failed
(Eject command time-out.)
• Press the Enter button to reboot.
• Ensure the drive shows good status
through the drive status window.
• Deactivate the drive using the GUI control
panel maintenance menu.
• Reseat drive.
• Load/unload a cartridge to the drive to
verify.
• Check the tape cartridge used in the last
operation for damage.
• Run the cartridge cycle diagnostic to
verify.
Table 10 Fault Symptom Codes (continued)
FSC Message ERP