Troubleshooting126
503D Drive Status Fail
(Cleaning operation failed because the
library could not retrieve drive status.)
• Press the Enter button to clear the
message.
• Invalid user initiated operation. Set
parameters correctly and try again.
• Ensure the drive shows good status
through the drive status window.
6001 Inter-Module Unknown Event
(Inter-module communication failure.)
• Press Enter to reboot.
• Check pass-through connections.
• Check network connections to the
network router.
6002 Inter-Module no command matching
response
• Verify operation and retry.
• Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
6003 Inter-Module command length
(Incorrect command length.)
• Verify operation and retry.
• Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
6004 Inter-Module loopback buffer mismatch • Cycle power to the library or reboot by
using the LCD touch display.
•Retry operation.
6005 Inter-Module bad data length
(Incorrect data length.)
• Verify operation and retry.
• Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
6006 Inter-Module bad packet length
(Incorrect packet length.)
• Verify operation and retry.
• Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
6007 Inter-Module failed to allocate TCP buffer • Power cycle the library.
• Check pass-through connections.
6008 Inter-Module pending table full • Power cycle the library.
• Retry the operation.
7001 Command response from unexpected
source
• Press the Enter button to reboot.
• Cycle power to the library or reboot
using the GUI touch screen.
Table 10 Fault Symptom Codes (continued)