A SERVICE OF

logo

VES-1000 Series Ethernet Switch
Firmware and Configuration File Maintenance 10-9
WARNING!
DO NOT INTERUPT THE FILE TRANSFER PROCESS AS THIS MAY PERMANENTLY DAMAGE
YOUR VES-1000 SERIES SWITCH.
10.4.1 Firmware File Upload
FTP is the preferred method for uploading the firmware and configuration. To use this feature, your computer
must have an FTP client.
When you telnet into the VES-1000 Series switch, you will see the following screens for uploading firmware and
the configuration file using FTP.
Figure 10-13 Telnet Into Menu 24.7.1 - Upload System Firmware
10.4.2 Configuration File Upload
You see the following screen when you telnet into menu 24.7.2.
Menu 24.7.1 — System Maintenance — Upload System Firmware
To upload the system firmware, follow the procedure below:
1. Launch the FTP client on your workstation.
2. Type "open" and the IP address of your system. Then type "root" and
SMT password as requested.
3. Type "put firmwarefilename ras" where "firmwarefilename" is the name
of your firmware upgrade file on your workstation and "ras" is the
remote file name on the system.
4. The system reboots automatically after a successful firmware upload.
For details on FTP commands, please consult the documentation of your FTP
client program. For details on uploading system firmware using TFTP (note
that you must remain on this menu to upload system firmware using TFTP),
please see your manual.
Press ENTER to Exit: