BMC74300BMC74399 227
BMC74335I ASAM USER EXIT exitname FOR DDN=ddname, WAS IN CONTROL AT
THE TIME OF THE ABEND
Explanation: The application sequential access method (ASAM) controller has
determined that the ASAM user exit routine (exitname) for the indicated ddname was
in control at the time of the abend.
System Action: Processing continues.
User Response: Correct the problem with the ASAM user exit routine and resubmit
the job.
BMC74336E AR/CTL FOR VSAM FILE REQUEST HANDLER HAS ENDED
PREMATURELY, WITH SYSTEM CODE system code, RETURN CODE rc
FOR DDN=ddname
Explanation: The APPLICATION RESTART CONTROL (AR/CTL) for VSAM
file request handler has ended prematurely for the VSAM file identified by the given
ddname. The message displays a system code and a return code (rc) associated with
the error.
System Action: AR/CTL abnormally terminates the task with abend U1775 and
reason code X00074336.
User Response: Contact BMC Software Product Support for assistance, and have
the job step listing available when you call.
BMC74337E AR/CTL FOR VSAM FILE REQUEST HANDLER HAS ENDED WITH
SYSTEM CODE system code, RETURN CODE rc FOR DDN=ddname
Explanation: The APPLICATION RESTART CONTROL (AR/CTL) for VSAM
file request handler has ended for the VSAM file indicated by the given ddname. The
message displays a system code and a return code (rc) associated with the error.
System Action: AR/CTL abnormally terminates the task with abend U1775 and
reason code X00074337.
User Response: Message BMC74336E indicates why the file request handler
ended. Contact BMC Software Product Support for assistance, and have the job step
listing available when you call.
BMC74338I AR/CTL FOR VSAM FILE REQUEST HANDLER COMPLETED
REPOSITION FOR DDN=ddname, WITH RETURN CODE rc
Explanation: The APPLICATION RESTART CONTROL (AR/CTL) for VSAM
file request handler has completed repositioning for the VSAM file indicated by the
given ddname. The message displays a return code (rc) associated with this action.
System Action: Processing for the task continues.
User Response: This message is for your information only. No action is necessary.