BMC44200BMC44299 83
WRITE ERROR HAS OCCURRED, DDNAME = ddname
Explanation: The given data set (ddname) being written by the BATCH
CONTROL FACILITY (BCF) Physical Logger has encountered a write error. A
possible system or physical device error has occurred. Refer to the job log data set
for any MVS messages.
System Action: The log data set is marked in error and DBRC is notified. If dual
logging is active, processing continues with the remaining log data set. If dual
logging is not active or if both logs are bad, the job step terminates.
User Response: If there are MVS messages in the job log data set, refer to them for
further error information. If no messages are in the job log data set, obtain a
SYSUDUMP data set and contact BMC Software Product Support for assistance.
BMC44217I DATASET NOT CLOSED, WRITE ERROR, DDNAME = ddname,
LSN = lsn
Explanation: The given data set (ddname) being written by the BATCH
CONTROL FACILITY (BCF) Physical Logger was not closed because it
encountered a
WRITE error. A possible system or physical device error has occurred.
The LSN value (lsn) is the sequence number of the last log record in the last valid
block that was written to the log data set. This number may be needed when using
the IMS Log Recovery utility.
System Action: Processing continues.
User Response: This message is for your information only. No action is necessary.
It provides information that may be necessary to close the log data set if the
execution controller cannot recover the job log data set. Have the job log data set
available if you need to contact BMC Software Product Support for assistance.
BMC44218I DYNAMIC LOG DATA SET CREATED, BLOCKS = number blks
Explanation: A dynamic log data set was specified, and the environment
supported dynamic backout. The dynamic log was created to provide dynamic
backout if needed. number blks shows a value in the range 1-32767.
System Action: Processing continues.
User Response: This message is for your information only. No action is necessary.
BMC44219I DYNAMIC BACKOUT (BKO=Y) ACTIVATED
Explanation: An execution option requested IMS dynamic backout for the job
step, but the IMS execution parameters did not specify
BKO=Y. BATCH CONTROL
FACILITY (BCF) has changed the environment to include IMS backout processing
for the job step execution.
System Action: Processing continues.
User Response: This message is for your information only. No action is necessary.