![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/7e/27e4df2a-2443-43a6-a856-72e36112a2da/27e4df2a-2443-43a6-a856-72e36112a2da-bg106.png)
BMC Software, Inc., Confidential and Proprietary Information
250 Application Enhancement Solutions Messages Manual
System Action: The job step terminates abnormally with a U1551 abend.
User Response: Correct the product initialization problem, or set the Force
Execution option for this product to N.
BMC74412E TERMINATION WAS REQUESTED BY product
Explanation: The product requested the Application Enhancement Solutions
(AES) application supervisor to abend the job step. The job log contains additional
messages indicating why the product requested the job step to be terminated.
System Action: The job step terminates abnormally with a U1551 abend.
User Response: Correct the indicated product problem.
BMC74413I REATTACHING PROCESS, FUNCTION=function. REATTACH
REQUESTED BY product. (count)
Explanation: The application abended. The product has requested that the
Application Enhancement Solutions (AES) application supervisor reattach the
application. The message provides the count of reattach attempts, which includes
reattaches, unit-of-work (UOW) retries, and product-requested resumptions.
System Action: The application is reattached.
User Response: This message is for your information only. No action is necessary.
BMC74414I ALLOCATION ERROR; DD=ddname
Explanation: The Application Enhancement Solutions (AES) application
supervisor encountered an error when it attempted to allocate a data set. The message
contains the ddname of the data set associated with the allocation attempt.
System Action: The AES application supervisor also issues message BMC74418I;
this message contains the details about the MVS SVC99 error that occurred.
User Response: For ddname AESPRINT, you can circumvent the problem by
adding the AESPRINT DD statement to the job step JCL. For other ddnames, have
the job log data set available and contact BMC Software Product Support.
BMC74415E INTERNAL LOGIC ERROR; REASON=rc
Explanation: The Application Enhancement Solutions (AES) application
supervisor or an AES product detected an internal logic error.
System Action: The job step terminates abnormally with a U1551 abend.
User Response: Have the reason code available and contact BMC Software Product
Support.