BMC150068E RESTORING WORKING STORAGE AT FILE OPEN OR FIRST I/O
REQUIRES AUTO CHKP/RSRT DDNAME.
Explanation: APPLICATION RESTART CONTROL (AR/CTL) detected that
the application program was using the Automatic Restart option and the value of the
Restore Working Storage option was FILEOPEN or FRSTFLEI but the value of
the Trigger DDname option was missing.
System Action: If the Application Enhancement Solutions Force AR/CTL
Execution option is set to Y, the job step terminates abnormally with abend U1553. If
this option is set to N, the job step continues without AR/CTL.
User Response: Specify the ddname of the automatic checkpoint trigger file as the
value of the Trigger DDname option.
BMC150069E RESTORING WORKING STORAGE AT CURSOR OPEN REQUIRES
AUTO CHKP/RSRT CURSOR NAME.
Explanation: APPLICATION RESTART CONTROL (AR/CTL) detected that
the application program was using the Automatic Restart option and the value of the
Restore Working Storage option was CRSROPEN but the Trigger Cursor Name
option value was missing.
System Action: If the Application Enhancement Solutions Force AR/CTL
Execution option is set to Y, the job step terminates abnormally with abend U1553. If
this option is set to N, the job step continues without AR/CTL.
User Response: Specify the cursor name of the automatic checkpoint trigger cursor
as the value of the Trigger Cursor Name option.
BMC150070E AR/CTL FOR DB2 CURSOR CONTROLLER RECEIVED A SECOND
INITIALIZATION REQUEST
Explanation: The APPLICATION RESTART CONTROL (AR/CTL) for
DB2*
cursor controller received a second initialization request from the AR/CTL main
controller. This condition indicates an internal error.
System Action: The task terminates abnormally with abend U1785 and reason code
X’00150070’.
User Response: Ensure that the load library concatenation is correct. Ensure that
the installation of AR/CTL was performed correctly. If you cannot determine the
cause of the problem, contact BMC Software Product Support.