Chapter 19 RMON-Lite
GS-1524/GS-1548 User’s Guide
130
The following table describes the labels in this screen.
19.5.1 RMON Alarm: Create New Alarm
Use the RMON Alarm: Create New Alarm screen to configure RMON alarms.
Click Create new Alarm view the screen as shown.
You can also click an alarm index entry in the RMON Alarm: Overview screen to
edit an existing alarm configuration.
Table 60 RMON Alarm: Overview
LABEL DESCRIPTION
RMON MIB
Table:
Use this drop down list box to select the MIB table you want to view.
Click Apply to refresh the screen to the selected MIB table view.
Refresh Click this to update all the fields in the RMON Alarm: Overview screen.
Create new
Alarm
Click this to view the RMON Alarm: Create New Alarm screen where you
can configure the parameters for an alarm.
Index This field displays the alarm configuration index number. Click this
number to edit the alarm entry.
Interval (sec) This field displays the time interval (in seconds) between data samplings.
Variable This field displays the name of the MIB field whose data is to be sampled.
Sample Type This field displays the method of obtaining the sample value
(absoluteValue or deltaValue).
Value This field displays the value of the statistic during the last sampling
period. This value is for comparing against the RisingThreshold and
FallingThreshold values.
Startup Alarm This field displays the alarm type (1:rising, 2:falling, or
3:risingOrFallingAlarm) that can be sent when this alarm is first
activated.
RisingThreshol
d
This field displays the rising threshold value set up for this alarm.
FallingThresho
ld
This field displays the falling threshold value set up for this alarm.
Rising Event
Index
This field indicates the index number of the event entry which
corresponds to the time when the alarm threshold was crossed.
Falling Event
Index
This field indicates the index number of the event entry which
corresponds to the time when the alarm threshold was crossed.
Owner This field displays the name of the creator of this entry.