A SERVICE OF

logo

KP915GV Product Manual
33
2.21 Reliability and Environmental
Table 5. Environmental Specifications
Characteristic State Value
Operating 0
o
C to +55
o
C
Operation above +30° C reduces the maximum operational
relative humidity.
Operating
gradient
±5°C per minute
Temperature
(ambient)
Storage
-40
o
C to +85
o
C, 5°C per minute maximum excursion
gradient.
Operating 10% to 85% RH non-condensing at +30
o
C, linearly
decreasing to 5% to 15.5% RH non-condensing at +65
o
C.
Relative
humidity
Storage 5% to 90% RH non-condensing at +40
o
C.
Operating Random 5Hz to 2kHz, 7.7grms, 10 mins in each of 3 axes
5Hz to 20Hz: 0.004g2/Hz ramping up to 0.04g2/Hz;
20Hz to 1000Hz: 0.04g2/Hz;
1000Hz to 2000Hz: 0.04g2/Hz ramping down to
0.01g2/Hz
Vibration
Packaged Random 5Hz to 2kHz, 9.7grms, 10 min. in each of 3 axes
5Hz to 20Hz: 0.006g2/Hz ramping up to 0.06g2/Hz;
20Hz to 1000Hz: 0.06g2/Hz;
1000Hz to 2000Hz: 0.06g2/Hz ramping down to
0.02g2/Hz
Sine 5Hz to 500Hz, 0.15 octave/min up and back, 10 min.
dwell at 3 resonances in each of 3 axes
5 to 50Hz swept – 0.1g; 50 to 500Hz swept – 0.25g
Non-
operating
30g 11ms, half-sine Shock
Packaged Drop test, 10-up bulk packaging, 30 inches free-fall, 152
inches/s velocity change
Operating To 15000 ft. (4500m) Altitude
Storage To 40000 ft. (12000m)
MTBF The table below summarizes the MTBF (hr) predictions for
the listed products, without the main processor, memory, or
battery installed.
SKU
35°C 55°C
KPGV1W00
298,735 141,946
KPGV1G00 295,736 156,014
KPGVFG00 280,528 147,801
Airflow Base on standard Intel guidelines
Fuses Self-resetting PTC fuse (fuses automatically reset without
user intervention once the load had been removed)