197
Software Fixes in Release K.11.12 - K.13.49
Release K.13.21
■ X2 Transceivers (PR_0000004758) — Some ProCurve SR and ER X2-10GbE (J8436A,
J8437A) transceivers have a timing issue that prevents the transceivers from being correctly
identified either when hot swapped or during a cold boot.
■ LEDs (PR_0000005623) — Upon insertion of a removable transceiver – either X2 or SFP
- the link LED fails to light for the 2 second-long indication of insertion confirmation.
■ Event Log (PR_0000005624) — A failed "removable" transceiver results in two event log
messages rather than just one.
■ Authentication (PR_0000005582) — Sometimes PC in the PC-phone tandem
authentication does not get authorized on its untagged VLAN.
Release K.13.21
The following problems were resolved in release K.13.21 (never released).
■ CLI (PR_1000760929) — Output from the CLI command show name int <port list> fails
to display the port number for interfaces with numbers larger than 9.
■ Config (PR_0000003638) — Fastboot can be configured, but then it cannot be disabled.
■ Multicast Filter (PR_0000002988) — Multicast filters may become corrupted following
their initial configuration, save and subsequent switch reload.
■ Self-Test (PR_0000001406) — The failure of a single module within a Switch 8212zl or
5400zl chassis may cause false self-test failures for other installed modules.
■ CLI (PR_0000005300) — The displayed output of the CLI command show ip pim rp-set
is not properly formatted.
■ CLI (PR_0000005302) — The displayed output of the CLI command show ip pim pending
is not properly formatted.
■ CLI (PR_1000782972) — An incorrect line voltage value may be displayed in the output
of the show system power CLI command.
■ CLI (PR_0000005381) — Attempts to perform a copy flash <primary|secondary> at the
CLI of a 8212zl switch running K.13.05 or higher will fail with the following error.
Flash-to-flash copy of product code failed
■ Config (PR_1000781011) — Copying a config onto a switch allows the appearance of an
invalid flow control setting (enabled) on half duplex ports.
■ Config (PR_1000781015) — When the MDIX-mode is configured for dual-personality
ports, copying a config onto a switch fails and produces a message about config file
corruption.